OEM CAPABILITY
BRAND REPUTATION
PRODUCTION ADVANTAGE
GLOBAL AFTER-SALES SERVICE

- PRODUCT PARAMETERS -

Product Description

The single-phase distribution transformer is small in size and light in weight, allowing it to be installed deep within load centers, shortening the radius of the low-voltage network and reducing energy losses.

Product Features

  • When the power supply radius of a three-phase distribution transformer is too large, the load density is low, and the voltage at the end of power lines drops, affecting normal user electricity, installing a single-phase distribution transformer at the end of the power supply line can shorten the low-voltage power supply radius and solve the problem of low user voltage.
  • When a three-phase distribution transformer is overloaded, a single-phase distribution transformer can be installed on an appropriate branch line based on load characteristics to transfer load and solve the problem of capacity increase.
  • Installing a single-phase distribution transformer in residential areas with no three-phase electricity demand will shorten the low-voltage power supply radius and reduce losses.
  • Installing a single-phase distribution transformer in areas with low load density, wide distribution, and no three-phase electricity can reduce investment and solve the problem of long-distance power supply.

Installation Method

According to user requirements, we can provide a pole-mounted installation structure, which is convenient for installation and reduces material costs for substation areas.

Technical Parameters

Rated Capacity(kVA)Rated Voltage(kV)Short-circuit Impedance(%)ConnectionSymbolNo-Load Losses(W)Load Losses(W)No-Load Current(%)

HVLV




56 / 6.3 / 10 / 10.5 / 112×(0.22–0.24) or 0.22–0.243.5II0 / II6281304.0
10



442343.5
16



523283.2
20



643873.0
30



805002.8
40



1006982.5
50



1208552.3
63



14410222.1
80



16012602.0
100



19214851.9
125



22817551.8
160



213021301.7
Notes:
  1. The performance parameters of other capacity products shall be determined through consultation between the manufacturer and the user.
  2. For combination transformers with low voltage of 2×(0.22–0.24) kV, when the low voltage is (0.22–0.24) kV, the capacity is reduced by 50% (except for parallel operation).
  3. For short-circuit impedance and short-circuit current, they shall be determined after consultation between the manufacturer and the user.

- Factory Display -

  • 8ebc9248-5567-4b90-8293-530f2bea2b51
  • f833243f-21d5-4c27-85f1-48ea62d2035a
  • 各型号油变
  • F4BA7CB8-C91D-49F4-8DA2-BF65ACF5D041
  • AF725E83-B062-4094-8D67-0AB513738C55
  • 438E03F5-3659-4EED-BDEB-F6FCF372ECBE
  • 52C7AF0F-74FB-4B0B-8927-24666120499E
  • 无取向硅钢仓库
  • 微信图片_20260120145905_111_31

- Certificate Display -

  • 8EE8273D-9715-46C2-B219-42C60A672722
  • A549B709-00CC-49A6-9262-15CCCE7A765B
  • B821D377-57AA-4245-B46E-485193D3F909
  • 1D019AF5-1A19-4347-BF1B-2E8050CBABBE
  • 1D019AF5-1A19-4347-BF1B-2E8050CBABBE2
  • 9A596275-62D3-45E5-A071-198F661B53B9
  • A742C588-2C8E-48AA-98C2-B2D5FDAA61C6
  • A742C588-2C8E-48AA-98C2-B2D5FDAA61C62
  • A54737C4-F34C-4132-8D49-302D680568B0
  • A54737C4-F34C-4132-8D49-302D680568B02
  • C37E0833-0B8E-4EF3-83D5-BBCC6B841820
  • C37E0833-0B8E-4EF3-83D5-BBCC6B8418202
  • CF04CDE9-D411-4214-A15E-EBB6C8E79C4C
  • CF04CDE9-D411-4214-A15E-EBB6C8E79C4C2
  • CF04CDE9-D411-4214-A15E-EBB6C8E79C4C3
  • CF04CDE9-D411-4214-A15E-EBB6C8E79C4C4
  • F5B1053E-9812-4841-A122-A95499D12FD3
  • F5B1053E-9812-4841-A122-A95499D12FD32
  • F5B1053E-9812-4841-A122-A95499D12FD33
  • F5B1053E-9812-4841-A122-A95499D12FD34

- Inquire Now -

We have established long-term and stable strategic partnerships with high-quality enterprises in various fields, and have won the widespread recognition and trust of our partners.

  • acs-logo (1)
  • corm (1)
  • CPOWER (1)
  • DC (1)
  • nuen (1)
  • RG_Logo-Black (1)
  • TES (1)
  • tess (1)
  • vega (1)
Submit

- Related Product -